POWER SUPPLY:
|
PROTECTION:
|
S - models
Q - models
Si - models
AMPLIFIER TYPE | Dual H-Bridge, 4 Quadrant |
CURRENT CONTROL | 4 state PWM at 20 kHz |
OUTPUT CURRENT | ST5 Series 0.1 – 5.0 amps/phase in 0.01 amp increments ST10 Series 0.1 – 10.0 amps/phase in 0.01 amp increments |
POWER SUPPLY | ST5 Series External 24 – 48 VDC Power Supply Required ST10 Series External 24 – 80 VDC Power Supply Required |
INPUT VOLTAGE RANGE | ST5 Series 18 – 53 VDC ST10 Series 18 – 88 VDC |
PROTECTION | Over-Voltage, Under-Voltage, Over-Temp, Motor/wiring shorts (Phase-to-Phase, Phase-to-Ground). |
IDLE CURRENT REDUCTION | Reduction range of “0 – 90%” of “Running Current” after delay selectable in milliseconds. |
AMBIENT TEMPERATURE | 0 to 55°C (32 – 158°F) (ST10 must be mounted to suitable heatsink). |
HUMIDITY | 90% non-condensing. |
MICROSTEP RESOLUTION | Software selectable from 200 to 51,200 steps/rev in increments of 2 steps/rev. |
ANTI-RESONANCE | (Electronic Raises the system damping ratio to eliminate midrange instability and allow stable operation throughout the speed range Damping) and improves settling time. |
TORQUE RIPPLE SMOOTHING | Allows for fine adjustment of phase current waveform harmonic content to reduce low-speed torque ripple in the range 0.25 to 1.5 rps. |
AUTO SETUP | Measures motor parameters and configures motor current control and anti-resonance gain settings. |
SELF TEST | Checks Internal & External Power supply voltages. Diagnoses open motor phases and motor resistance changes >40%. Detects encoder wiring and signal faults (differential encoder only). |
MICROSTEP EMULATION | Performs high resolution stepping by synthesizing fine microsteps from coarse steps (Step & Direction Mode Only). |
COMMAND SIGNAL SMOOTHING | Software configurable filtering reduces jerk and excitation of extraneous system resonances (Step & Direction Mode Only). |
NON-VOLATILE STORAGE | Configurations are saved in FLASH memory on-board the DSP. |
MODE OF OPERATION | Step & Direction, CW/CCW, A/B Quadrature, Oscillator, Joystick, SCL, Hub. |
STEP AND DIRECTION INPUTS | Optically Isolated, Differential, 5 Volt. Minimum pulse width = 250 ns. Maximum pulse frequency = 2 MHz. Function: Step & Direction, CW/CCW Step, A/B Quadrature, Run/Stop & Direction, Jog CW & CCW or CW & CCW Limits, Adjustable bandwidth digital noise rejection filter. |
ENABLE INPUT | Optically Isolated, 5-12 Volt. Function: Motor Enable, Alarm Reset or Speed Select (Oscillator Mode). |
OUTPUT | Optically Isolated, 24V, 10mA MAX. Function: Fault, Motion, Tach. |
ANALOG INPUT RANGE | 0 to 5 VDC |
ANALOG INPUT RESOLUTION | 12 bits |
COMMUNICATION INTERFACE | RS-232 |
NON-VOLATILE STORAGE | Programs, Data and drive configuration are saved in FLASH and EEPROM memory |
INPUTS |
X1, X2 Optically Isolated, differential, 5 Volt. Minimum pulse width = 250 ns. Maximum pulse frequency = 2 MHz. Function: Step & Direction, CW/CCW Step, A/B Quadrature, Encoder Following, Sensor, Home or Branch Select. X3 Optically isolated, 12 - 24V, sourcing or sinking. Function: Motor Enable, Sensor, Home or Branch Select. X4 Optically isolated, 12 - 24V, sourcing or sinking. Function: Alarm Reset, Sensor, Home or Branch Select. X5, X6 Optically isolated, 12 - 24V, sourcing or sinking. Function: Jogging, Sensor, Home or Branch Select. NOTE: Inputs X3 – X6 have a shared “Common”. X7, X8 Optically isolated, differential, 12 - 24V. Function: CW & CCW Limits, Sensor, Home or Branch Select. |
OUTPUTS |
Y1 Optical darlington, 30V, 100mA max, NPN/sinking. Function: General purpose programmable. Y2 Optical darlington, 30V, 100mA max, NPN/sinking. Function: Motion, tach or general purpose programmable. Y3 Optical darlington, 30V, 100mA max, NPN/sinking. Function: Fault or general purpose programmable. NOTE: Y1, Y2 & Y3 have a shared “Common”. Y4 Optical darlington, 30V, 100mA max, configurable as sinking or sourcing. Function: General purpose programmable. |
TWO ANALOG INPUTS RANGE | Software selectable: 0-5V, ±5V, 0-10V, ±10V. |
RESOLUTION | 12 bits (with ±10V signal range) 11 bits (with 0-10V or ±5V signal range) 10 bits (with 0-5V signal range) |
ENCODER OPTION | Differential line receivers suitable rates to 2 MHz. Employs encoder to provide STALL DETECTION and STALL PREVENTION with static position maintenance. |
COMMUNICATION INTERFACE | RS-232 standard, optional RS-485. |
AGENCY APPROVALS | RoHS CE EN 61800-3: 2004 EN 61800-5-1: 2003 |